GitHub ↗
● RESEARCH PROTOTYPE · ISTANBUL ANATOLIAN BASIN

Urban-Heat-Aware Micro-Mobility Routing Architecture

An open empirical routing prototype integrating multi-sensor satellite Land-Surface Temperature (LST), physics-based stop-and-go energy dissipation, and Arrhenius battery state-of-health degradation into an NSGA-II multi-objective frontier. Designed to analyze thermal exposure tradeoffs against travel efficiency without heuristic obfuscation.

LST Peak Range (22 Jul 2025)

19.9–51.7 °C

Δ31.8 °C intra-urban thermal variance

Spatial Grid Resolution

30 m

Landsat 8/9 & MODIS daily fusion

Pilot Graph Footprint

~810 km²

Kadıköy · Üsküdar · Ataşehir

Fused Temporal Window

177 Days

Continuous season time-series

01 / Methodology

Five-Stage Deterministic Pipeline

Seed: 42
STAGE 01LST FUSION

Satellite Imagery Fusion

Landsat 30m spatial accuracy combined with MODIS daily repeat frequency via anomaly blending; diurnal cycle modeled via sinusoidal 14:00 peak.

177-day daily series @ 30m
STAGE 02SPATIAL AUTOCORR

Hotspot Extraction

Moran's I confirms strong positive spatial clustering (0.966). Getis-Ord Gi* with FDR correction isolates statistically significant microclimate cells.

393 hot / 609 cold clusters
STAGE 03PHYSICS & MCMC

Dissipation Model

Baseline kinematics (rolling, aerodynamic, slope forces) derated by drivetrain temperature curves. 4-state Markov-chain simulation adds urban stop-and-go acceleration penalties.

4.13 → 9.0 Wh/km (+118%)
STAGE 04ELECTROCHEMICAL

Arrhenius Degradation

Capacity retention calibrated on NASA PCoE 18650 cycling experiments across five thermal regimes. Activation energy constrained to 45 kJ/mol (LCO literature) to prevent overfitting.

RMSE: 0.000237/cycle (T ≥ 15°C)
STAGE 05PARETO OPTIMIZATION

Bi-Objective Routing

Road network edges attributed with thermal degree-hours and joule cost. NSGA-II computes trade-off frontiers over parameter alpha between minimal energy and minimal heat exposure.

157,248 attributed edges
02 / Experimental Workbench

Integrated Microclimate & Telemetry Lab

Dual-Engine Interactive
Spatial Canvas & Multi-Objective Route Trace Üsküdar ↔ Ataşehir
14:00 (Peak LST)
04:00 (Min)14:00 (Peak)22:00 (Night)
α = 0.50
0.0 (Coolest) 1.0 (Cheapest)
| — hover the map — | Mean: 36.2 °C @ 14:00
Coolest Direct
Coordinate bbox: [40.95, 29.00, 41.05, 29.18]OSMnx Graph attribution: SRTM 30m
Pareto Frontier Readout NSGA-II Opt
Energy 213 Wh
Heat Stress 75.0 °C·km
Route Nodes 176 nodes (97–255)
Trip energy (Wh) Thermal stress (°C·km)
← Coolest (Low stress)Cheapest (Low Wh) →
25°C
15km/h
0°
Instantaneous Steady Dissipation
4.13 Wh/km
MCMC City Cycle 9.0 Wh/km +118% stop-and-go
03 / Empirical Results

Validation Metrics & Sensitivity Baseline

Saved Validation Artifacts

Stop-and-Go MC Mean

9.0 Wh/km

6–15 Wh/km literature band

Constant-Speed Gap

+118%

4.13 vs 9.0 Wh/km

Moran's I @ 300m

0.966

p < 0.001 spatial cluster

Non-Degenerate Fronts

2 / 6

Valid heat-route tradeoff

Graph Complexity

61,378

Nodes · 157,248 edges

Objective Correlation

r = 0.9475

Energy ↔ heat exposure

Model Sensitivity & Calibration

Parameter DimensionConstant-Speed / DefaultCalibrated ModelPhysical Implication
Kinematic Energy Consumption4.13 Wh/km→9.0 Wh/km+118% correction under urban stop-and-go acceleration cycles
Non-Degenerate Pareto Fronts0 / 3 OD pairs→2 / 6 OD pairsDemonstrates active heat-vs-distance trade-off along coastal/inland corridors

Methodological Scope & Boundary Conditions

1. LST vs Ambient Air Temperature

Land-Surface Temperature (LST) derived from thermal radiometers measures asphalt/canopy radiation, not ambient air or internal battery-core temperatures. 51.7 °C asphalt surfaces frequently coexist with 30–35 °C ambient air.

2. Synthetic Demand & Operator Isolation

Travel origination-destination points are algorithmically simulated across the 810 km² graph. Operational fleet telemetry is decoupled via an extensible, swappable TripDataProvider architectural interface.

3. Electrochemical Regime Constraint

The Arrhenius capacity fade model applies exclusively to warm regimes (T ≥ 15 °C). Cold-temperature lithium plating mechanisms and long-duration calendar dwell-time ageing are outside this formulation scope.

04 / Architecture & Delivery

Service Interface & Execution Specification

MIT License

FastAPI Specifications

7 Endpoints · /docs
GET /health Service liveness, git commit hash & version
GET /heat-layer Diurnal LST snapshot (bbox, diurnal stats, raster grid)
GET /hotspots Getis-Ord Gi* hotspot GeoJSON (z-score, FDR p-value)
GET /route Pareto frontiers for validated bounding-box OD pairs
GET /metrics Verbatim model evaluation summary & pipeline seed
GET /soh Arrhenius retention curve calculator (temp, cycles)
GET /energy Kinematic mechanical dissipation breakdown
curl "localhost:8000/energy?distance_m=3000&speed_kmh=15&temp_c=25"

Local Reproduction & Quickstart

Python 3.11+ · uv
# 1. Clone repository & configure environment
git clone https://github.com/Exoristos/coolroute.git
cd coolroute && uv sync --extra dev && cp .env.example .env

# 2. Run offline validation suite (254 tests)
uv run pytest tests/ -q
uv run ruff check .

# 3. Spin up API and Streamlit research dashboard
uv run uvicorn uhi_battery.api.app:app --port 8000
uv run streamlit run src/uhi_battery/dashboard/app.py
Deterministic Seed: 42 Local-First (No external network) MIT Open Source